AJD 275

Woodlands Generators

230/400 V - 50 Hz

Generating Set Model

AJD 275

Power
Pf. 0,8

Standby kVA

275

Prime kVA

250

Standby:Continuous running at variable load for duration of an emergency.No overload is permitted on these ratings. In accordance with BS 5514, ISO 3046

Prime:Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period.Contact us for the other running periods. In accordance with ISO 8528, BS 3046.

DESIGN SPECIFICATIONS

  • High quality, reliable and complate power unit
  • Compact design
  • Easy start and maintenance possibility
  • Every generating set is subjected to a comprehensive test programme which includes full load testing and checking and providing of all control and safety shut down functions testing
  • Full engineered with a wide range of options and accessories:Canopy,soundproof canopy and on road trailer

STANDARD GENSET SPECIFICATIONS

ENGINE:

  • JOHN DEERE heavy duty diesel engine
  • Four cycle,water cooled,turbo charged and intercooled
  • Direct injection fuel system
  • Mechanical governor control system
  • Replaceable wet type cylinder liners
  • 12 V D.C. starter and charge alternator
  • Replaceable cartridge type air filter,fuel filter and oil filter
  • Cooling raditor and fan
  • Flexible fuel connection hoses and sump oil drain valve
  • Industrial capacity exhaust silencer and steel bellows
  • Starter battery (with lead acid)including rack and cables
  • Jacket water heater (at automatic models)
  • Manual and circuit diagram documents

ALTERNATOR:

  • Brushless, single bearing system, 4 poles
  • Insulation class H
  • Standard degree of protection IP21
  • Self-exciting and self-regulating
  • Solid state automatic voltage regulator
  • Stator winding with 2/3 pitch for improved harmonics
  • Vacuum impregnated windings with tropicalized epoxy varnished

CHASSIS:

  • Steel chassis and antivibration pads
  • Base frame design incorporates an integral fuel tank
  • The generating set can be lifted or carefully pushed / pulled by the base frame
  • Dial type fuel gauge and drain plug on the fuel tank

CANOPY:

  • All canopy parts are designed with modular principles
  • Without welding assembly
  • All metal canopy parts are painted by electrostatic polyester powder paint
  • Exhaust silencer manufactured from aluminium plated steel
  • Emergency stop push button is installed outside of canopy
  • Modular canopy can also be installed at a later date
  • Easy maintenance and operation
  • Easy lifting and moving
  • Thermally insulated engine exhaust system

QUALITY STANDARDS:

  • The equipment meets the following standards: ISO 3046, VDE 0530, BS 4999, BS 5000, IEC 34-1. The generating set is manufactured by a full accredited ISO 9001 NQA.

WARRANTY:

  • 12 months warranty from commissioning date as standard.

CONTROL SYSTEM:

Control, supervision and protection panel is mounted on the genset base frame.The control panel is equipped as follows:

1. Auto Mains Failure Control System - P2020

  • Control with DSE 5220 Module
  • Static battery charger
  • Emergency stop push button

Control Module Features: DSE 5220

  • Automatic engine starting and stopping
  • Front panel programming of the module settings
  • Remote communication via RS 232 port or RS 485 "modbud" output
  • Scrolling digital LCD display
  • Event logging of shutdown alarms
  • Monitoring AC mains supply
  • Provides signal to change over switch gear
  • Easy push button control: Stop-Reset / Auto / Manual / Test / Start

Metering via LCD Display:

  • Generator Volts (F - F / F - N)
  • Generator Amperes (L1, L2, L3)
  • Generator Frequency (Hz)
  • Generator kVA
  • Generator kW
  • Generator Cos
  • Mains frequency (Hz)
  • Engine oil pressure (PSI & Bar)
  • Engine Temperature (°F / °C)
  • Engine speed RPM
  • Engine hours run
  • Plant battery volts
  • Mains Volts (F - F / F - N)

Alarms

  • Under / Over generator volts
  • Under / Over generator frequency
  • Over current
  • Low oil pressure
  • High engine temperature
  • Under / Over speed
  • Under / Over mains volts
  • Can data fail
  • Low coolant level
  • Fail to start
  • Fail to stop
  • Emergency Stop
  • Charge fail
  • Low / High battery volts
  • Under / Over mains frequency
  • Can ECU fail

2. Power outlet terminal board mounted on the genset base frame

TECHNICAL DATA

Diesel Generating Sets 230/400 V - 50 Hz

G
R
O
U
P

MODEL

AJD 275

Power
Pf. 0,8

275
220

250
200

D
I
E
S
E
L

E
N
G
I
N
E

Engine Make

John Deere

Model

6081 H

Gross engine power output at rated rpm

kWm
hp

268
359

Aspiration and Cooling

Turbo charged & charge cooled

Cylinders Capacity

Lt

8.1

Cylinders and Build

6 In line

Engine Speed

rpm

1500

Bore and Stroke

mmxmm

116x129

Compression Ratio

15.7:1

Governor

Mechanical

Fuel Consumption

Load
L/hr

1/2

3/4

Full

28

41

55

Fuel Tank Capacity

Lt

420

Oil Capacity

Lt

32

Coolant Capacity (Radiator and Engine)

Lt

44

Air Intake - Engine

m³/min

17.3

Exhaust Gas Flow

m³/min

47.3

Alternator Voltage Regulation

± %1

OPEN TYPES

Dimensions (length x width x height)

mm

2900x1150x1900

Dry weight

kg

2120

SOUND ATTENUATED TYPE

Canopy Model

ASM 7

Dimensions (length x width x height)

mm

4000x1210x2050

Dry weight

kg

2860

* Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.

OPTIONAL EQUIPMENTS

* Fuel water separator filter

* 3 pole outlet circuit breaker

* Automatic fuel filling system

* Oil heater

* Low fuel level alarm

* Tool kit

* Over sized alternator

* Electronic governor control

* Transfer switch 3 pole

* Charge ammeter

* Anti condensation heater

* Transfer switch 4 pole

* Bulk fuel tank

* Manual oil drain pump

* Oil temperature shutdown

* Automatic sychronising and power control system

* Earth fault, single set

* Residential silencer

* Enclosure, sound proof canopy

* Trailer